Fire-rated and cement board partitions
Fire-rated partition contractor in Egypt: gypsum and cement board walls
FUTURE builds fire-rated gypsum partitions, cement board partitions and claddings as part of the ceiling package, so walls and ceilings meet without gaps in the fire line. We delivered them at Giza Palace Hotel & Spa, our largest project.
Last updated
- C stud 75 mm, 600 c/c
- U track 75 mm at floor; deep-leg track at the head
- Fire-rated gypsum board, 2 × 12.5 mm each side (type F / DF), joints staggered; EI 90 typ.
- Mineral wool in the cavity
- Screws: inner layer 750 max, outer layer 250 max c/c
- Deflection head: 20 mm movement gap, boards not fixed to the head track
- Fire-rated sealant at head, base and abutments
- Anchors to slab and floor, 1000 max c/c
- Sealing strip under tracks and at the wall stud
01
What is a fire-rated gypsum partition?
FUTURE builds fire-rated gypsum partitions: drywall walls made from steel studs and fire-resistant gypsum boards, often with mineral wool in the cavity, tested to hold back fire for a set time such as 60 or 120 minutes. The rating belongs to the whole tested system: board type, number of layers, stud size and spacing, insulation and how the joints, head and penetrations are sealed. Change one part and the rating no longer applies.
02
Where fire-rated partitions are used in hotels and developments
The building's approved fire strategy sets which walls need a rating and how long. On hotels and multi-storey developments that typically includes:
- Walls between guest rooms and corridors
- Walls between neighbouring guest rooms or apartments
- Stair, lift and escape-route enclosures
- Service risers and shafts
- Plant rooms, kitchens and storage areas
Your fire consultant and the fire strategy decide the rating. We build to it.
03
When cement board is the better wall
Cement board is a dense board made with cement and reinforcement. It does not soften in water, so it suits wet-area walls behind tiles, areas exposed to impact or splashing, and claddings where gypsum would not last. At Giza Palace we built both fire-rated gypsum partitions and cement board partitions and claddings in the same package.
04
How does FUTURE keep a partition's fire rating intact on site?
FUTURE keeps a fire rating intact by building the exact tested system named in the specification, layer by layer, and by planning every penetration before boarding starts. The partition runs from the floor slab to the structural slab above, not just to the suspended ceiling. No board, stud or layer is substituted without the consultant's approval. In two-layer walls the joints are staggered as the tested system requires. The head uses a deflection detail, so the wall stays sealed when the slab above moves. Doors, access panels and glazing in the wall must carry the same rating as the wall itself. Every pipe, duct and cable that crosses a rated wall is shown on FUTURE's shop drawings, so each opening can be closed with a firestop product tested for that wall and that service. FUTURE built fire-rated gypsum partitions to this method at Giza Palace Hotel & Spa, Sheikh Zayed City, between 2022 and 2025.
05
Where has FUTURE built fire-rated partitions?
FUTURE built fire-rated gypsum partitions, cement board partitions and claddings at Giza Palace Hotel & Spa in Sheikh Zayed City, Giza, between 2022 and 2025. Giza Palace is FUTURE's largest project. It puts guest rooms and suites, corridors, a reception, a ballroom, a mall, meeting rooms and a casino under one roof, which means many different walls and ceilings meeting along corridors and around public areas. The partitions were part of the same contract as the hotel's gypsum board ceilings, gypsum ceiling tiles and Corniches cornices. Because walls and ceilings sat in one contract, the junctions between them, where a fire line most often fails, were FUTURE's responsibility from shop drawings to handover. For main contractors and developers, that is the practical reason to buy partitions and ceilings from the same firm. The Giza Palace case study lists the full scope of the package.
06FAQ
Fire-rated partition questions
It means a sample of that exact wall system kept fire from passing through, and kept the far side below set temperature limits, for 60 or 120 minutes in a standard furnace test. It describes the tested system. A wall built with different boards, fewer layers or unsealed gaps does not carry that rating.
Fire-resistant board alone does not make a rated wall; it is one part of one. The rating also depends on the number of layers, the studs, the insulation and the sealing of joints and penetrations, as set out in the tested system.
The building's fire strategy, prepared by the fire consultant and approved by the authorities. We build the walls to the ratings and systems it specifies.
Cables and pipes can pass through a fire-rated wall if each opening is sealed with a firestop product tested for that wall and that type of service. We plan penetrations on the shop drawings so none are left open.
Pricing rated walls?
Send the partition layout with the rating of each wall type and the specified systems.